Canpump CA logo
Canpump CA logo

All articles

Pressure Fluctuating/ Not SteadyUpdated 6 days ago

 

Problem 

Probable Cause 

Solution 

Pressure Fluctuating & not Steady 

Jammed valves 

Check & clean out if necessary 

Pump is sucking air  

Check inlet circuit and possibility of air ingress 

Worn packings 

Check & replace if necessary 

Worn nozzle 

Check & replace if necessary 


Please reach out to us [email protected] after this troubleshoot with your order number and findings. A short video/photos of the system would be very helpful.

Was this article helpful?
Yes
No