Canpump Help Center logo
Canpump Help Center logo

All articles

Pressure Drop in HosesUpdated 37 minutes ago

Pressure Drop in Hoses

The table below shows pressure loss (in PSI per 100 feet of hose) for various flow rates and hose internal diameters, helping you select the right hose size to minimize friction loss.


Water Flow in US GPM 

Actual Internal Diameter (inches) 

1/4 

5/16 

3/8 

1/2 

5/8 

3/4 

1 

1 1/4 

1 1/2 

2 

2 1/2 

0.5 

16 

5 

2 

 

 

 

 

 

 

 

 

1 

54 

20 

7 

2 

 

 

 

 

 

 

 

2 

180 

60 

25 

6 

2 

 

 

 

 

 

 

3 

380 

120 

50 

13 

4 

2 

 

 

 

 

 

4 

 

220 

90 

24 

7 

3 

 

 

 

 

 

5 

 

320 

130 

34 

10 

4 

 

 

 

 

 

6 

 

 

220 

52 

16 

7 

1 

 

 

 

 

8 

 

 

300 

80 

25 

10 

2 

1 

 

 

 

10 

 

 

 

120 

38 

14 

3 

2 

1 

 

 

15 

 

 

 

250 

80 

30 

7 

4 

2 

 

 

20 

 

 

 

 

120 

50 

12 

6 

3 

1 

 

25 

 

 

 

 

200 

76 

19 

9 

4 

1 

 

40 

 

 

 

 

410 

162 

42 

15 

6 

2 

1 

60 

 

 

 

 

 

 

93 

32 

13 

3 

1 

70 

 

 

 

 

 

370 

126 

43 

18 

4 

1 

80 

 

 

 

 

 

 

55 

23 

5 

2 

1 

90 

 

 

 

 

 

 

68 

28 

7 

2 

1 

100 

 

 

 

 

 

 

82 

34 

8 

3 

1 

125 

 

 

 

 

 

 

124 

51 

12 

4 

2 

150 

 

 

 

 

 

 

 

72 

18 

7 

2 

Was this article helpful?
Yes