All nozzles were tested at 1,000 psi using water at 70℉ (21.1℃). The room humidity was between 40-50% during the tests. The patternation measurements were conducted using the SETscan OP600 patternator that can measure sprays up to a maximum diameter of 7″.
Orifice | Contour based angle |
0.10 / .004″ | 19.90° |
0.15 / .006″ | 55.70° |
0.20 / .008″ | 72.50° |
0.30 / .012″ | 74.60° |
0.40 / .016″ | 82.00° |
0.50 / .020″ | 72.50° |
0.60 / .024″ | 91.00° |
0.80 / .032″ | 105.80° |
1.00 / .040″ | 106.90° |
1.20 / .048″ | 114.00° |